Listing# 587277

WATERS ALLIANCE SYNAPT HDMS Q-TOF Mass Spectrometer


Seller's Acceptable Currency:

$70,800.00 USD

Make An Offer

Location:North America

Level of Removal:Uncrated/Loose

Why we recommend inspection

*All offers are submitted in Seller’s Acceptable Currency

Don't see what you're looking for?b0b体育平台




Equipment Description
Waters SYNAPT HDMS Q-TOF Mass Spectrometer

The Waters SYNAPT HDMS Q-TOF Mass Spectrometer ( QTOF LCMSMS MSD G1 High Definition Mass Spectrometry Quadruple Time of Flight ) is designed for leading researchers working at the limits of conventional mass spectrometry capabilities who need to further characterize and define their samples, Waters SYNAPT HDMS System offers unique, enabling functionality. Waters SYNAPT HDMS System enables the analysis of samples differentiated by size and shape, as well as mass, to deliver increased specificity and sample definition beyond that achievable by conventional mass spectrometers.System Includes:
  • Computer & Software
  • Edwards XDS 35i Roughing Pump
  • SYNAPT HDMS Q-TOF MSMS
Optional:
  • ACQUITY UPLC System
  • 的SYNAPT hdm系统操作员可以在两种模式:a) TOF mode b) Mobility-TOF mode TOF Mass Resolution in Positive Ion a) V Mode: 10,000 measured on the (M 6H)^6 isotope cluster from bovine insulin (m/z 956) b) W Mode: 17,500 measured on the (M 6H)^6 isotope cluster from bovine insulin (m/s 956) TOF Mass Resolution in Negative Ion a) V Mode: 10,000 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431) b) W Mode: 17,500 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431) Positive Ion MS Sensitivity a) V Mode: The peak at m/z 556 from a solution of 50 pg/?L leucine enkephalin in 50/50 acetonitrile/water 0.1% formic acid, infused at a flow rate of 5 ?L/min, will have an intensity of greater than 1,700 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin) and the mass range will be set to 1,000 Da. b) EDC: The peak at m/z 556 from a solution of 10 pg/?L leucine enkephalin in 50/50 acetonitrile/water 0.1% formic acid, infused at a flow rate of 5 ?L/min, will have an intensity of greater than 2,000 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), with sensitivity set to a maximum at 556 Da. Negative Ion MS Sensitivity: V Mode: The peak at m/z 503 from a solution of 500 pg/?L raffinose in 70/30 acetonitrile/water (no additives), infused at a flow rate of 5 ?L/min, will have an intensity of greater than 1,800 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), and the mass range will be set to 1,000 Da. Positivt Ion MS/MS Sensitivity V Mode: Using a [Glu]-Fibrinopeptide B solution of 100 fmol/?L, at a flow rate of 5 ?L/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the most intense y" sequence ion from the MS/MS spectrum of the doubly charged precursor ion (785.8 Da) will be greater than 130 counts per second. This will correspond to a signal to noise ratio of greater than 50:1 (after a 3x9 smooth) on the most intense y" sequence ion, for a 1 second scan. The instrument mass range will be set to 2,000 Da. Negative Ion MS/MS Sensitivity V Mode: Using a solution of 500 pg/?L raffinose in 70/30 acetonitrile/water, at a flow rate of 5 ?L/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the fragment ion at 179.1 Da in the MS/MS spectrum of the precursor ion at 503.2 Da will be greater than 130 counts per second. The instrument mass range will be set to 1,000 Da. Mass Scale Calibration Accuracy The mass measurement accuracy of the instrument in V-mode, using an internal lockmass, is such that the RMS error between the measured and the accepted masses of peaks which have sufficient intensity, and are free from interference from other masses, will be less than 2 ppm over the range of 150-900 Da. Mass Measurement Accuracy The mass measurement accuracy of the instrument, in W-mode, will be better than 2 ppm RMS, based on 10 consecutive repeat measurements of the [M Na]^ ion of raffinose (m/z 527.1588), using the [M H]^ ion of leucine enkephalic (556.2771) as the LockSpray lockmass. Analyte lockmass peaks must have sufficient intensity and be free of interference from other masses. Mass Range: The TOF mass range is 20 - 100,000 Da in V-mode, and 20 - 26,500 Da in W-mode. The quadrupole mass range in non-resolving mode is 20 - 16,000 Da for a 4,000 Da quadrupole, and 20 - 32,000 Da for an 8,000 Da quadrupole. Note: Licenses for Waters’ software products are not transferable. Any customer who purchases Waters products are advised that in order to hold a valid license to use the Waters’ software, they must purchase a license and appropriate Application Manager directly from Waters.


Note: Stock Photos - not exact representation of equipment.

Specifications:
Standard
Metric
Manufacturer Name
Waters

Model:
SYNAPT HDMS Q-TOF
SYNAPT HDMS Q-TOF

Type of Mass Spec:
Q-TOF
Q-TOF

Recommended Packaging Form:
6C (6X6X6)
6C (6X6X6)


Dimensions:
Standard
Metric

Overall:
1 x 1 x 1 IN - 1 Pounds
25.40 x 25.40 x 25.40 mm - 0.45 kg

Disclaimer

This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in

the USA.

This equipment is subject to a removal and loading charge.


这个联合提供的书面描述t is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

Please be aware that weights and dimensions of equipment provided on EquipNet’s listings are estimates and can vary from actual weights and size. Sellers estimates are often not precise especially when equipment was installed versus prepped for shipment. As such, please do not fully rely on the accuracy of this information in EquipNet’s listings for shipping quotes and/or user size requirements.

Any license associated with this equipment is non-transferable.

Customers who viewed this item also viewed this